×

Free shipping for most orders over $75     Most orders processed before 2:30 pm EST, ship same day
Mon - Fri 8am - 5pm EST | Phone: (804) 236-3881

Product Documentation:

DMV-DLE 703/624L, Double Solenoid Valve with VLA, 120 V, 80 VA, by Dungs 267083

$1,724.35
Item Code: 267083
DMV-DLE 703/624L With VLA (267083) - 1”, 1-1/4”, 1-1/2”, 2” NPT or Rp 120 Vac (+10%/-15%) 50-60 Hz, 80 VA NEMA Type 4 Replacement Coil: 246516 (Coils Sold Individually) Formerly: 244-165VP Description The DUNGS Dual Modular Valve (DMV-D(LE)/622) incorporates overtravel and a proof of closure switch which is factory mounted and set with a Vent Line Adapter (VLA) that is also factory installed. For main gas lines: • Up to 1 1/2”; vent line must be 3/4” • 2”; vent line must be 1” Application The DMV-VLA is recommended for industrial and commercial heating applications that require two safety shutoff valves with valve 2 Incorporating overtravel and a proof of closure switch with a vent line connection between the safety shutoff valves and NEMA Type 4x enclosure. The DMV-D(LE)/624 is suitable for natural gas, propane, butane, air and other inert gases. Specifications Body Size Pipe Size/ Thread Vent Line Connection DMV 702/624 1” – 2” NPT or Rp 1” NPT DMV 703/624 1” – 2” NPT or Rp 1” NPT Max Operating Pressure 7 PSI (500 mbar) UL, FM 5 PSI (360 mbar) CSA Electrical Ratings (+10%/-15) 110 – 120 Vac/ 50-60 Hz Enclosure Rating NEMA Type 4 Electrical Connection Screw terminals with ½” NPT conduit connection Operating Time 100% Duty Cycle Ambient Temperature Rating -20 F to +140 F (-30 C to +60 C) Aluminum body; Inlet, intermediate and outlet side taps (G1/8 ISO 228); Inlet gas strainer installed in the housing upstream valves (23 mesh screen); DMV-D - V1 fast opening & closing (<1 s), V2 fast opening & closing (<1 s); DMV-DLE - V1 fast opening & closing (<1s); V2 slow opening 20s MAX @ 70F & fast closing (<1 s); V2 on both models feature a manually adjustable flow rate (<10-100%); 100% duty cycle; Refer to Flow Curves for Body Selection. Includes 1 POC switch. Flanges must be ordered and priced separately. Code requirements vary. FM requires visual indication on 1" and larger safety valves. The visual indicator, (VI) 266949 meets this requirement. The visual indicator must be ordered separately for valve 1. Factory mounted and calibrated proof of closure switch: SPDT 10 A resistive, 8 FLA, 48 LRA @ 120 Vac; NEMA type 4; - 40 °F to +150 °F (-40 °C to +65 °C); Switch incorporates visual indication of valve (opened & closed).