DMV-DLE 703/602, Double Solenoid Valve with VLA, 120 V, 90 VA, by Dungs 266974

$1,343.31
Item Code: 266974
DMV-DLE 703/602 With VLA (266974) - 1”, 1-1/4”, 1-1/2”, 2” NPT or Rp 120 Vac (+10% / -15) 50-60 Hz, 90 VA NEMA Type 12 Replacement Coil: 232403 Replacement PWB: 238806 Formerly: 224-847V Description The DUNGS Dual Modular Valve with Vent Line Adapter (DMV-VLA) combines all the features of the DUNGS Dual Modular Valve with a factory installed vent line connection between the two automatic shutoff valves. For main gas lines: • Up to 1 1/2”; vent line must be 3/4” • 2”; vent line must be 1” Application The DMV-VLA is recommended for industrial and commercial heating applications that require two safety shutoff valves in series with a vent line connection between the safety shutoff valves. The DMV-VLA is suitable for natural gas, propane, butane, air and other inert gases. Optional Approvals When ordered and installed with Burkert connector plug (part number 253731), the UL Recognized DMV valve may replace a UL Listed valve. Such a substitution is typically required for equipment UL Listed to UL 295/UL 795. Specifications Body Sizes Pipe Size/ Thread Vent Line Connection DMV 701/602 ½” – 1” NPT or Rp ¾” NPT DMV 702/602 1” – 2” NPT or Rp 1” NPT DMV 703/602 1” – 2” NPT or Rp 1” NPT Max. Operating Pressure 7 PSI (500 mbar) UL, FM 5 PSI (360 mbar) CSA Electrical Ratings (+10% / -15%) 110 – 120 Vac/ 50-60 Hz 24 Vac / 50-60 Hz 24 Vdc Enclosure Rating NEMA 12 Electrical Connection DIN-connector with ½” NPT Conduit Adapter Operating Time 100% Duty Cycle Ambient Temperature Rating -40 F to +150 F (-40 C to +65 C) Aluminum body; Inlet, intermediate and outlet side taps (G1/8 ISO 228); Inlet gas strainer installed in the housing upstream valves (23 mesh screen); DMV-D - V1 fast opening & closing (<1 s), V2 fast opening & closing (<1 s); DMV-DLE - V1 fast opening & closing (<1s); V2 slow opening 20s MAX @ 70F & fast closing (<1 s); V2 on both models feature a manually adjustable flow rate (<10-100%); 100% duty cycle; Refer to Flow Curves for Body Selection. Conduit Adapter (240671), DIN connector (210319), and flanges must be ordered and priced separately. Code requirements vary. FM requires visual indication on 1" and larger safety valves. Two visual indicators, (VI) 266949 or one CPI 400 (CPI) 266968, and one VI meet this requirement. These also must be ordered separately.