DMV-DLE 703/602, Double Solenoid Valve, 24 V, 90 VA, by Dungs 228225

$1,223.84
Item Code: 228225
DMV-DLE 703/602 (228225) - 1”, 1-1/4”, 1-1/2”, 2” NPT or Rp 24 Vac (+10%/-15%) 50-60 Hz, 90 VA NEMA Type 12 Replacement Coil: 238822 Replacement PBW: 238806 Formerly: 228-225 Description The DUNGS Dual Modular Valve (DMV-D(LE)/602) combines two normally closed, automatic shutoff valves in one compact housing, which can be wired independently or in parallel. Valve 1 (V1) of the DMV-D and DMV-DLE series is fast opening and fast closing. Valve 2 (V2) of the DMV-D is fast opening, while V2 of the DMV-DLE is slow-opening for smoother light-off. Max. flow adjustment on V2 provides variable main flow on both models. Application The DMV/6 is recommended for industrial and commercial heating applications that require two safety shutoff valves in series. The DMV is suitable for natural gas, propane, butane, air and other inert gases. Optional Approvals When ordered and installed with Burkert connector plug (part number 253731), the UL Recognized DMV valve may replace a UL Listed valve. Such a substitution is typically required for equipment UL Listed to UL 295/UL 795. Specifications Body Sizes Pipe Size/ Thread DMV-D(LE) 701/602 ½” – 1” NPT or Rp DMV-D(LE) 702/602 1” – 2” NPT or Rp DMV-D(LE) 703/602 1” – 2” NPT or Rp Max. Operating Pressure 7 PSI (500 mbar) UF, FM 5 PSI (360 mbar) CSA Electrical Ratings (+10% / -15%) 110 - 120 Vac / 50-60 Hz 24 Vac/50 – 60 Hz; 24 VDC Enclosure Rating NEMA Type 12 Electrical Connection DIN-connector with ¾” NPT conduit adapter Operating Time 100% Duty Cycle Ambient Temperature Rating -40 F to +150 F (-40 C to +65 C) Aluminum body; Inlet, intermediate and outlet side taps (G1/8 ISO 228); Inlet gas strainer installed in the housing upstream valves (23 mesh screen); DMV-D - V1 fast opening & closing (<1 s), V2 fast opening & closing (<1 s); DMV-DLE - V1 fast opening & closing (<1s); V2 slow opening 20s MAX @ 70F & fast closing (<1 s); V2 on both models feature a manually adjustable flow rate (<10-100%); 100% duty cycle; Refer to Flow Curves for Body Selection. Conduit Adapter (240671), DIN connector (210319), and flanges must be ordered and priced separately. Code requirements vary. FM requires visual indication on 1" and larger safety valves. Two visual indicators, (VI) 266949 or one CPI 400 (CPI) 266968, and one VI meet this requirement. These also must be ordered separately.