Free shipping for most orders over $75     Most orders processed before 2:30 pm EST, ship same day
Mon - Fri 8am - 5pm EST | Phone: (804) 236-3881

Product Documentation:

DMV-DLE 702/622, Double Solenoid Valve with V.I., 120 V, 65 VA, by Dungs 267020

$1,347.88
Item Code: 267020
DMV-DLE 702/622 With V.I. (267020) - 1”, 1-1/4”, 1-1/2”, 2” NPT or Rp 120 Vac (+10%/-15%) 50-60 Hz, 65 VA NEMA Type 12 Replacement Coil: 232402 Replacement PWB: 238806 Formerly: 230-792PI Description The DUNGS Dual Modular Valve (DMV-D(LE)/622) combines all the features of the DUNGS Dual Modular Valve DMV-D(LE)/6 plus valve 2 incorporates overtravel and a proof of closure switch which is factory mounted and set. The Visual Indicator (VI) (266949) is factory mounted to Valve 1 (V1) Application The DUNGS DMV/622 is recommended for industrial and commercial heating applications that require two safety shutoff valves with valve 2 incorporating overtravel and a proof of closure switch. The DMV/622 is suitable for natural gas, propane, butane, air and other inert gases. Optional Approvals When ordered and installed with Burkert connector plug (part number 253731), the UL Recognized DMV valve may replace a UL Listed valve. Such a substitution is typically required for equipment UL Listed to UL 295/UL 795. Specifications Body Size Pipe Size/ Thread DMV 701/622 ½” – 1” NPT or Rp DMV 702/622 1” – 2” NPT or Rp DMV 703/622 1” – 2” NPT or Rp Max Operating Pressure 7 PSI (500 mbar) UL, FM 5 PSI (360 mbar) CSA Max. Close Off Pressure 10 PSI (700 mbar) UL, FM Electrical Ratings (+10%/-15) 110 – 120 Vac/ 50-60 Hz 24 Vac/ 50-60 Hz 24 Vdc Enclosure Rating NEMA Type 12 Electrical Connection DIN-Connector With ½” NPT Conduit Adapter Operating Time 100% Duty Cycle Ambient Temperature Rating -40 F to +150 F (-40 C to +65 C) Aluminum body; Inlet, intermediate and outlet side taps (G1/8 ISO 228); Inlet gas strainer installed in the housing upstream valves (23 mesh screen); DMV-D - V1 fast opening & closing (<1 s), V2 fast opening & closing (<1 s); DMV-DLE - V1 fast opening & closing (<1s); V2 slow opening 20s MAX @ 70F & fast closing (<1 s); V2 on both models feature a manually adjustable flow rate (<10-100%); 100% duty cycle; Refer to Flow Curves for Body Selection. Conduit Adapter (240671), DIN connector (210319), and flanges must be ordered and priced separately. Code requirements vary. FM requires visual indication on 1" and larger safety valves. The visual indicator, (VI) 266949 meets this requirement. Factory mounted and calibrated proof of closure switch: Factory mounted visual indicator: SPDT 10 A resistive, 8 FLA, 48 LRA @ 120 Vac; NEMA type 4; -40 °F to +150 °F (-40 °C to +65 °C); Switch incorporates visual indication of valve (opened & closed).